Reconditioning the Cleaver Brooks Boilers, Hurst Boilers, Johnston Boilers, Superior Boilers, Williams & Davis Boilers includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel, tubes, boiler trim piping, and blowdown piping and valves, new Honeywell or Fireye controls are installed, new electrical and control panels are installed as needed, new steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes is in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included.
Used, reconditioned Cleaver Brooks Boilers, Hurst Boilers, Johnston Boilers, Superior Boilers, Williams & Davis Boilers, 3 & 4 pass dry back boilers, 3 & 4 pass wet back boilers, high pressure boilers, low pressure boilers, hot water boilers, boiler feed water systems, atmospheric tanks, pressurized deaerators, blow down tanks, blow down separators, flash steam economizers, stack economizers, boiler flame safeguard controls, boiler combustion controls, boiler water level controls.
Item # |
Year |
Horsepower |
Manufacturer |
Pressure |
Steam or Hot Water |
Burner |
Fuel(s) |
|---|---|---|---|---|---|---|---|
| 9230 9230/Asset/Boiler.JPG | Year N/A 1992 | Horsepower N/A 30 hp | Manufacturer N/A Superior | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A PowerFlame | Fuel(s) N/A natural gas |
| 9530 9530/Asset/Hurst-Image.jpeg | Year N/A 1995 | Horsepower N/A 30 hp | Manufacturer N/A Hurst System Skid | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A PowerFlame | Fuel(s) N/A natural gas |
| 2240 2240/Asset/Hurst-Image.jpeg | Year N/A 2022 | Horsepower N/A 40 hp | Manufacturer N/A Lattner Vertical Boiler Feed, Blowdown, etc | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A PowerFlame | Fuel(s) N/A natural gas |
| 9170 9170/Asset/other-boilers.jpg | Year N/A 1991 | Horsepower N/A 70 hp | Manufacturer N/A York Shipley | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A York-Shipley | Fuel(s) N/A natural gas/oil |
| 9480 9480/Asset/Cleaver-brooks-400HP.PNG | Year N/A 1994 | Horsepower N/A 80 hp | Manufacturer N/A Cleaver Brooks | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A Cleaver Brooks | Fuel(s) N/A natural gas |
| 95100 95100/Asset/Cleaver-brooks-400HP.PNG | Year N/A 1995 | Horsepower N/A 100 hp | Manufacturer N/A Cleaver Brooks | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A PowerFlame | Fuel(s) N/A natural gas |
| 09100 09100/Asset/Hurst-Image.jpeg | Year N/A 2009 | Horsepower N/A 100 hp | Manufacturer N/A Hurst | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A PowerFlame | Fuel(s) N/A natural gas |
| 11150 11150/Asset/Boiler.JPG | Year N/A 2011 | Horsepower N/A 150 hp | Manufacturer N/A Superior | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A PowerFlame | Fuel(s) N/A natural gas |
| 99200 99200/Asset/Cleaver-brooks-400HP.PNG | Year N/A 1999 | Horsepower N/A 200 hp | Manufacturer N/A Cleaver Brooks CBLE | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A Cleaver Brooks 30 PPM | Fuel(s) N/A natural gas |
| 97250 97250/Asset/Cleaver-brooks-400HP.PNG | Year N/A 1997 | Horsepower N/A 250 hp | Manufacturer N/A Cleaver Brooks CBLE | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A Cleaver Brooks 60 PPM | Fuel(s) N/A gas |
| 95300 95300/Asset/Cleaver-brooks-400HP.PNG | Year N/A 1995 | Horsepower N/A 300 hp | Manufacturer N/A Cleaver Brooks | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A Cleaver Brooks 30 PPM | Fuel(s) N/A gas/2 oil |
| 10300 10300/Asset/Hurst-Image.jpeg | Year N/A 2010 | Horsepower N/A 300 hp | Manufacturer N/A Superior | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A PowerFlame 30 PPM NOx | Fuel(s) N/A natural gas |
| 07300 07300/Asset/Hurst-Image.jpeg | Year N/A 2007 | Horsepower N/A 300 hp | Manufacturer N/A Hurst Hybrid Biomass | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A Underfeed Stoker | Fuel(s) N/A biomass |
| 04350 04350/Asset/Cleaver-brooks-400HP.PNG | Year N/A 2004 | Horsepower N/A 350 hp | Manufacturer N/A Cleaver Brooks ICB | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A Cleaver Brooks 30 PPM NOx | Fuel(s) N/A natural gas |
| 07500 07500/Asset/sup-boiler.jpg | Year N/A 2007 | Horsepower N/A 500 hp | Manufacturer N/A Superior | Pressure N/A 150 psi | Steam or Hot Water N/A Steam | Burner N/A Industrial Combustion | Fuel(s) N/A natural gas |
| 97700 97700/Asset/Boiler.JPG | Year N/A 1997 | Horsepower N/A 700 hp | Manufacturer N/A Cleaver Brooks | Pressure N/A 200 psi | Steam or Hot Water N/A Steam | Burner N/A Cleaver Brooks | Fuel(s) N/A natural gas |