Reconditioning the Cleaver Brooks Boilers, Hurst Boilers, Johnston Boilers, Superior Boilers, Williams & Davis Boilers includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel, tubes, boiler trim piping, and blowdown piping and valves, new Honeywell or Fireye controls are installed, new electrical and control panels are installed as needed, new steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes is in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included.
Used, reconditioned Cleaver Brooks Boilers, Hurst Boilers, Johnston Boilers, Superior Boilers, Williams & Davis Boilers, 3 & 4 pass dry back boilers, 3 & 4 pass wet back boilers, high pressure boilers, low pressure boilers, hot water boilers, boiler feed water systems, atmospheric tanks, pressurized deaerators, blow down tanks, blow down separators, flash steam economizers, stack economizers, boiler flame safeguard controls, boiler combustion controls, boiler water level controls.
| Items |
9230 30 HP Ready to Ship Used Boiler List Price Quote
|
/Asset/Hurst-Image.jpeg 9530 Hurst Boilers List Price Quote
|
/Asset/Hurst-Image.jpeg 2240 Used Boilers by Horsepower List Price Quote
|
/Asset/other-boilers.jpg 9170 70 HP York Shipley Boiler List Price Quote
|
9480 Cleaver Brooks Boilers List Price Quote
|
|||||
| Number | N/A | N/A 1 | N/A | N/A | N/A | |||||
| Year | N/A 1992 | N/A 1995 | N/A 2022 | N/A 1991 | N/A 1994 | |||||
| Horsepower | N/A 30 hp | N/A 30 hp | N/A 40 hp | N/A 70 hp | N/A 80 hp | |||||
| Manufacturer | N/A Superior | N/A Hurst System Skid | N/A Lattner Vertical Boiler Feed, Blowdown, etc | N/A York Shipley | N/A Cleaver Brooks | |||||
| Description | N/A | |||||||||
| Pressure | N/A 150 psi | |||||||||
| Steam or Hot Water | N/A Steam | |||||||||
| Burner | N/A PowerFlame | N/A PowerFlame | N/A PowerFlame | N/A York-Shipley | N/A Cleaver Brooks | |||||
| Fuel(s) | N/A natural gas | N/A natural gas | N/A natural gas | N/A natural gas/oil | N/A natural gas | |||||
|
|
||||||||||

