Print Back
Reconditioning the used Cleaver Brooks Boiler(s) includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel. Additionally tubes, boiler trim piping, and blow down piping and valves and new Honeywell or Fireye controls are installed along with new electrical and control panels are installed as needed. New steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included.

Used, reconditioned Cleaver Brooks Boilers, Cleaver Brooks 3 & 4 pass dry back boilers, Cleaver Brooks 3 & 4 pass wet back boilers, Cleaver Brooks water tube boilers, high pressure boilers, low pressure boilers, hot water boilers, Cleaver Brooks boiler feed water systems, atmospheric tanks, pressurized deaerators, blow down tanks, blow down separators, flash steam economizers, stack economizers, boiler flame safeguard controls, boiler combustion controls, boiler water level controls.
Cleaver brooks 400HP
Unit of Measure
1 

Item #

Year

Horsepower

Manufacturer

Pressure

Steam or Hot Water

Burner

Fuel(s)

0360 N/A 2003 N/A 60 hp N/A Cleaver Brooks N/A 150 psi N/A Steam N/A ProFire N/A natural gas
03100-2 N/A 2003 N/A 100 hp N/A Cleaver Brooks N/A 150 psi N/A Steam N/A Cleaver Brooks N/A natural gas
03100-1 N/A 2003 N/A 100 hp N/A Cleaver Brooks N/A 150 psi N/A Steam N/A Cleaver Brooks N/A natural gas/oil
93125 N/A 1993 N/A 125 hp N/A Cleaver Brooks N/A 200 psi N/A Steam N/A Cleaver Brooks N/A natural gas
95150 N/A 1995 N/A 150 hp N/A Cleaver Brooks CBLE N/A 150 psi N/A Steam N/A Cleaver Brooks 30 PPM NOx N/A natural gas/oil
99150 N/A 1999 N/A 150 hp N/A Cleaver Brooks CEW N/A 150 psi N/A Steam N/A ProFire 30 PPM NOx N/A natural gas
91200 N/A 1991 N/A 200 hp N/A Cleaver Brooks N/A 200 psi N/A Steam N/A Cleaver Brooks N/A natural gas/oil
96300 N/A 1995 N/A 300 hp N/A Cleaver Brooks CBLE N/A 150 psi N/A Steam N/A Cleaver Brooks 30 PPM NOx N/A natural gas/oil
09350CB N/A 2009 N/A 350 hp N/A Cleaver Brooks CBLE N/A 250 psi N/A Steam N/A Cleaver Brooks 30 PPM NOx N/A natural gas/oil
96400 N/A 1996 N/A 400 hp N/A Cleaver Brooks CBLE N/A 150 psi N/A Steam N/A Cleaver Brooks 30 PPM NOx N/A natural gas
02500 N/A 2002 N/A 500 hp N/A Cleaver Brooks N/A 300 psi N/A Steam N/A Cleaver Brooks N/A natural gas/oil
95500 N/A 1995 N/A 500 hp N/A Cleaver Brooks CBLE N/A 150 psi N/A Steam N/A Cleaver Brooks 30 PPM NOx N/A natural gas/oil
07750 N/A 2007 N/A 750 hp N/A Cleaver Brooks CBLE N/A 200 psi N/A Steam N/A Cleaver Brooks 30 PPM NOx N/A natural gas/oil
95800 N/A 1995 N/A 800 hp N/A Cleaver Brooks N/A 250 psi N/A Steam N/A Cleaver Brooks N/A natural gas
181500 N/A 2018 N/A 1500 hp N/A Cleaver Brooks CBEX N/A 200 psi N/A Steam N/A Cleaver Brooks 30 PPM NOx N/A natural gas
Unit of Measure
1