Reconditioning the used Cleaver Brooks Boiler(s) includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel. Additionally tubes, boiler trim piping, and blow down piping and valves and new Honeywell or Fireye controls are installed along with new electrical and control panels are installed as needed. New steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included.
Used, reconditioned Cleaver Brooks Boilers, Cleaver Brooks 3 & 4 pass dry back boilers, Cleaver Brooks 3 & 4 pass wet back boilers, Cleaver Brooks water tube boilers, high pressure boilers, low pressure boilers, hot water boilers, Cleaver Brooks boiler feed water systems, atmospheric tanks, pressurized deaerators, blow down tanks, blow down separators, flash steam economizers, stack economizers, boiler flame safeguard controls, boiler combustion controls, boiler water level controls.
| Items |
97250 250 HP/PPH Cleaver Brooks Boiler |
95300 300 HP Cleaver Brooks Boiler |
0360 Cleaver Brooks Boilers |
9480 Cleaver Brooks Boilers |
95100 Cleaver Brooks Boilers |
|||||
| Description |
N/A
4 pass dry-back Reconditioning the used Cleaver Brooks Boiler(s) includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel. Additionally tubes, boiler trim piping, and blow down piping and valves and new Honeywell or Fireye controls are installed along with new electrical and control panels are installed as needed. New steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included. Used, reconditioned Cleaver Brooks Boilers, Cleaver Brooks 3 & 4 pass dry back boilers, Cleaver Brooks 3 & 4 pass wet back boilers, Cleaver Brooks water tube boilers, high pressure boilers, low pressure boilers, hot water boilers, Cleaver Brooks boiler feed water systems, atmospheric tanks, pressurized deaerators, blow down tanks, blow down separators, flash steam economizers, stack economizers, boiler flame safeguard controls, boiler combustion controls, boiler water level controls. |
N/A
Reconditioning the used Cleaver Brooks Boiler(s) includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel. Additionally tubes, boiler trim piping, and blow down piping and valves and new Honeywell or Fireye controls are installed along with new electrical and control panels are installed as needed. New steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included. |
N/A
Reconditioning the used Cleaver Brooks Boiler(s) includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel. Additionally tubes, boiler trim piping, and blow down piping and valves and new Honeywell or Fireye controls are installed along with new electrical and control panels are installed as needed. New steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included. |
N/A
Reconditioning the used Cleaver Brooks Boiler(s) includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel. Additionally tubes, boiler trim piping, and blow down piping and valves and new Honeywell or Fireye controls are installed along with new electrical and control panels are installed as needed. New steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included. |
N/A
Reconditioning the used Cleaver Brooks Boiler(s) includes but not limited to the following: boilers re-tubed as required, cleaned on the fireside, waterside, outside, and painting, new fireside and waterside gaskets are installed, hydrostatic tests are done on the vessel. Additionally tubes, boiler trim piping, and blow down piping and valves and new Honeywell or Fireye controls are installed along with new electrical and control panels are installed as needed. New steam pressure controls are installed, the boilers are re-wired as needed, new safety relief valves are installed or shipped loose for field installation, electrical and mechanical checks are performed to identify defective components, defective components found are replaced. We guarantee that the pressure vessel and tubes are in good condition and that the boiler will pass a hydrostatic test at the time of startup. A one (1) year parts replacement warranty on controls is included. |
|||||
| Number | N/A 1 | N/A | N/A | N/A | N/A | |||||
| Year | N/A 1997 | N/A 1995 | N/A 2003 | N/A 1994 | N/A 1995 | |||||
| Horsepower | N/A 250 hp | N/A 300 hp | N/A 60 hp | N/A 80 hp | N/A 100 hp | |||||
| Manufacturer | N/A Cleaver Brooks CBLE | N/A Cleaver Brooks | N/A Cleaver Brooks CBE | N/A Cleaver Brooks | N/A Cleaver Brooks | |||||
| Description | N/A 4 pass dry-back | N/A | N/A | N/A | N/A | |||||
| Pressure | N/A 150 psi | |||||||||
| Steam or Hot Water | N/A Steam | |||||||||
| Burner | N/A Cleaver Brooks 60 PPM | N/A Cleaver Brooks 30 PPM | N/A ProFire | N/A Cleaver Brooks | N/A PowerFlame | |||||
| Fuel(s) | N/A gas | N/A gas/2 oil | N/A natural gas | N/A natural gas | N/A natural gas | |||||
|
|
||||||||||